![]() triplex is pretty expensive for 30ft so trying to reduce cost.Īlso need to know what size breaker for the inverter to ac distribution. explorist.life suggested 10awg triplex from shore power to inverter and 6awg from inverter to ac distribution with a 3000W 12V inverter but I assume I can go smaller since I am using 24V. Most importantly, I don't see any recommendations for triplex wire size from shore power to inverter or ac distribution to inverter. Could I just use 10awg for everything from busbarconverterdc block since I already have it prewired and have excess 10awg wire?Īre all the fuses listed, besides the shunt fuse, ANL or MEGA fuses?Īre the 30A fuses listed from converter to dc block actually fuses or breakers in the dc block? I have a preinstalled solar setup on the RV and 10awg wires are already routed to the battery from dc block. Just a couple questions to clarify everything. I have edited the explorist.life diagram to suit my setup for reference.Įverything else that has not been whited out I am using in my system except I am replacing the bmv-712 with a smartshunt.Ģ4->12V converter will be added for dc block.Īny tips or constructive criticism outside of the scope of my questions is welcomed. Sorry for all the questions but this is all I have left to figure out and would love to get it all sorted out so I can buy all the wiring/fuses necessary. Is 4/0 necessary from lynx to inverter, chassis ground, and batteries? (Answered: 1/0) Is 2awg from SCC to lynx correct for my system? (Answered: 4awg) What gauge wire from lynx to 12v dc block? (Answered: 10awg) What size ANL fuses at each connection in lynx distributor? (inverter, dc block, scc) (Answered: Inverter-250A, scc-150A, dc distribution-inline fuses)įrom shore power to inverter: What size triplex wire? (Answered: 10awg Triplex) RV is about 25 feet from inverter to breaker and from shore power to inverter so I would like to get 30 ft wire for clearance I am following the explorist.life diagrams and videos as well as various other resources (Will Prowse of course)įrom Inverter to Breaker box: what size triplex wire? what size breaker in ac distribution panel? I need some help figuring out wire sizing and fuse/breakers needed at a couple points in my build and haven't been able to find too much information relating to 24V systems. I have a 2022 Grand Design Transcend Xplor 231RK travel trailer (non-motorized) ![]() I am currently in the planning and buying phase of my solar upgrade on my RV. 200A continuous charge & discharge current and max. Note: In the event of a conflict between the voltage drop table and the ampacity table use the larger wire size.Hello everyone, this is my first post on the forum. Twice Larger Capacity: Ampere Time 24V 200Ah LiFePO4 supports max. Add together the current draw (amps) of all locks on the same circuit. Table X From ABYC E11 - CONDUCTORS SIZED FOR 10 PERCENT DROP IN VOLTAGE Access Control System WIRE GAUGE SIZE & DISTANCE CHART For 12V and 24V AC/DC. Length of Conductor from Source of Current to Device and Back to Source - Feetġ2 Volts - 3% Drop Wire Sizes (gauge) - Based on Minimum CM AreaĢ4 Volts - 3% Drop Wire Sizes (gauge) - Based on Minimum CM Area ![]() Note: In the event of a conflict between the voltage drop table and the ampacity table, use the larger wire size. Table IX From ABYC E11 - CONDUCTORS SIZED FOR 3 PERCENT DROP IN VOLTAGE Use the conductor length, the system voltage, and the ampacity, in conjunction with the appropriate volt drop table, i.e., 3 percent or 10 percent – TABLE IX or TABLE X, to determine conductor size. To use TABLE IX and TABLE X, measure the length of the conductor from the positive power source connection to the electrical device and back to the negative power source connection in feet. In the event of a conflict between the ampacity table and the voltage drop tables, the larger conductor size shall be used. ![]() Check the conductor size for compliance with the maximum allowable voltage drop. Conductors used for lighting, other than navigation lights, and other circuits where voltage drop is not critical, shall be sized for a voltage drop not to exceed 10 percent.Ĭonductor Size - To determine conductor size use TABLE IX or TABLE X. V oltage Drop - Conductors used for panelboard or switchboard main feeders, bilge blowers, electronic equipment, navigation lights, and other circuits where voltage drop must be kept to a minimum, shall be sized for a voltage drop not to exceed three percent. ![]()
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |